Shenzhen Epona Tech Ltd.
Main products:DC-DC Power Coverter,Mini Itx Motherboard,Power Module
Products
Contact Us
  • Contact Person : Ms. Cao Maggie
  • Company Name : Shenzhen Epona Tech Ltd.
  • Tel : 86-755-2573 5647
  • Fax : 86-755-2570 7850
  • Address : Guangdong,Shenzhen,B303, XiangFuGe, Phase2, Xianghuo Garden,Guowei Rd, Liantang, Luohu
  • Country/Region : China
  • Zip : 518004

120W AC DC Power Adaptor

120W AC DC Power Adaptor
Product Detailed
120W AC DC Power Adaptor AC input:100-240VAC DC output: 12V, 10A Efficincy: 50/60Hz CE. FCC, UL compliant

 120W AC DC Power Adaptor

1. Input Requirements

  

1-1. Input Voltage

 

100-240Vac

 

1-2. Input Frequency

 

50/60Hz

 

1-3. Input Current

1.)1.8 A Max, AT 115Vac, Full load.

2.)1.0 A Max, AT 230Vac, Full load.

 

1-4. Efficiency

 

When100-240Vac line input voltage (120Vac), the efficiency shall be 83% or better under maximum load.

1-5.No Load Power Consumption

 

The internal power loss at no load shall be less than 1W AT 264Vac.

 

1-6. Inrush Current

1.)40A Max.(AT 115Vac, Cold Start.)

2.)80A Max.(AT 230Vac, Cold Start.)

 

1-7. Turn-On Time

 

3.5 Seconds Max. (AT 115Vac, Cold Start)

 

1-8. Hold Up Time

 

10m Seconds Min. (AT 115Vac Full Load).

 

1-9. Configuration

 

2- Wire input AC line (Line, Neutral,).

 

1-10. Line Regulation

 

The maximum voltage change on DC output shall be within tolerance when AC input voltages varies within the range specified±2%.

1-11. Input Protection Device

 

An adequate internal fuse on the AC input line shall be protected

 

1-12. Hi-Pot Test

 

Primary-Secondary: 1.8KVac For 3 Seconds. (Leakage Current 10mA)

  

Insulation resistance shall be more than 100Mohm AT 500Vdc between primary line, Neutral line and secondary between primary line neutral line and frame ground. (F.G)

2. Output Requirements

 

2-1. Output Voltage and Current

 

 

 

Output Voltage

 

 

Tolerance

 

 

Output Current

 

 

+12Vdc

 

 

±5%

Min

Max

0A

10A

 

 

2-2. Output Voltage Regulation

 

The  total  output  voltage  regulation  shall  be  +5%,  including  the  effects  of  line  voltage variations, load current, ripple and noise. and the AC component of the load current.

2-3. Ripple and Noise

 

The power supply shall not exceed the following limits on the indicated voltage for 60Hz or

 

50Hz ripple, switching frequency ripple and noise measured with a 20MHz width

 

 

 

 

Output Voltage

 

Ripple and Noise

 

+12Vdc

120mV(Max)

 

Ripple and Noise: 50/60Hz Ripple +Switching Ripple and Noise

 

Ripple and noise are measured at the end of output cables which are added a 0.1uF(104) Ceramic capacitor and a 10uF Electrolytic capacitor (connect parallel)

2-4. Over Voltage Protection

 

The voltage will not exceed the upper trip limit. Use for ZENER diode

 

Output Voltage

Upper

11.4Vdc~12.6Vdc

 

2-5. Over Current Protection

  

When  the  adapter  output  current  is  over  14A should  be  shut  down  and  no  dangers  or hazardous .It can auto recover when remove away the short.

2-6. Short Circuit Protection

 

A Short circuit place at output will not cause damage to adapter it can auto recover when remove away the short.

2-7. Leakage Current

 

0.5mA Max. (AT 264Vac 50Hz).

  

 

3. Environmental Requirements

 

Temperature

1.)Operating:    0°C to +40°C

2.)Storage    :    -20°C to +80°C

 

 Humidity

  

1.)Operating:    10% to 90% non-condensing

2.)Storage    :    5% to 95% non-condensing

 

Dimensions (Case Size )

 

Length:   172mm Width :72mm Height:    42mm

 

Weight

 

Power unit: <350g. (Max)

120W AC DC Power Adaptor



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.